Automatic Changeover Switch When Mains Voltage Sags

An automatic changeover switch protects against complete power outages. However, sites can be affected by voltage dips and/or missing phases. Although there is some main supply, sensitive plant/equipment can suffer. At Blades Power Generation, we know these issues create difficulties for site managers, as the generator is delayed because a complete failure isn't identified.

Complete Failure v Abnormal Supply

If a system is set up to simply switch to generator on complete loss of supply, and not detecting partial failures, voltage dips may be missed. Within this scenario, equipment will continue to be affected by faulty supply and the generator will not engage.

Starting the Generator Before Complete Failure

It is important to have the correct switching logic. If the main supply is unreliable, the generator should start, and once it is ready, the load should be transferred. With source interlocking in place, it cannot be connected to both the main supply and the generator.

Returning to Main Supply

It is important to have a good switching set-up so that, when returning to the main supply, the system will only switch once the supply is stable.

 

Standard changeover switches will disconnect the supply and then connect the new supply. This causes a small interruption to supply. If this cannot be tolerated by your process, please let us know at an early stage so we can discuss options for you.

Selecting an Automatic Load Transfer Switch in the UK

To select an automatic load transfer switch in the UK for a 3-phase industrial application consider the following:


  • Number of Phases: Is it single-phase or three-phase?
  • Rating: Ensure it is rated for your full load, plus a sensible overload.
  • Generator compatibility: Ensure the system and control unit are compatible with your generator.
  • Control Unit Specification: Ensure it detects the problems that may occur at your site.

Improved Reliability at Blades Power Generation

We design bespoke ATS panels and 3-phase systems specific to your site. Using Deep Sea monitoring, we monitor the supply. We provide engineering support to design and set up your switching so that it is suitable for the issues that occur at your site.

If you are experiencing regular voltage dips and/or single-phase issues within your site, please give us details of the supply conditions, generator set-up and switching requirements. Our engineering team will be able to help you specify an Automatic Changeover Switch to allow quick switching, preventing issues with your equipment.

Configure your ATS panel online

Everything in this article is something we build and supply — configure it online or call 01453 799655.

Configure now →