Automatic Changeover Switch When Mains Voltage Sags
An automatic changeover switch protects against complete power outages. However, sites
can be affected by voltage dips and/or missing phases. Although there is some
main supply, sensitive plant/equipment can suffer. At Blades Power Generation,
we know these issues create difficulties for site managers, as the generator is
delayed because a complete failure isn't identified.
Complete Failure v Abnormal Supply
If a system is
set up to simply switch to generator on complete loss of supply, and not
detecting partial failures, voltage dips may be missed. Within this scenario,
equipment will continue to be affected by faulty supply and the generator will
not engage.
Starting the Generator Before Complete Failure
It is important
to have the correct switching logic. If the main supply is unreliable, the
generator should start, and once it is ready, the load should be transferred.
With source interlocking in place, it cannot be connected to both the main
supply and the generator.
Returning to Main Supply
It is important
to have a good switching set-up so that, when returning to the main supply, the
system will only switch once the supply is stable.
Standard
changeover switches will disconnect the supply and then connect the new supply.
This causes a small interruption to supply. If this cannot be tolerated by your
process, please let us know at an early stage so we can discuss options for
you.
Selecting an Automatic Load Transfer Switch in the UK
To select an
automatic load transfer switch in the UK for a 3-phase industrial
application consider the following:
- Number of Phases: Is
it single-phase or three-phase?
- Rating: Ensure it is
rated for your full load, plus a sensible overload.
- Generator
compatibility: Ensure the system and control unit are compatible with your
generator.
- Control Unit
Specification: Ensure it detects the problems that may occur at your site.
Improved Reliability at Blades Power Generation
We design bespoke ATS panels and 3-phase systems specific to your site. Using Deep Sea monitoring, we monitor the supply. We provide engineering support to design and set up your switching so that it is suitable for the issues that occur at your site.
If you are
experiencing regular voltage dips and/or single-phase issues within your site,
please give us details of the supply conditions, generator set-up and switching
requirements. Our engineering team will be able to help you specify an
Automatic Changeover Switch to allow quick switching, preventing issues